Your Cart

Products

Print

Draeger X-dock Calibration Station

Adams Fire 800-942-5880 Draeger Drager Dräger X-am 2500 5000 5600 Pac 3500 5500 Accuro Tubes X-act X-dock xam xdock xact CMS

Work Smarter, Work Safer

with the

Draeger X-dock®

 

Adams Fire 800-942-5880 Draeger Drager Dräger X-am 2500 5000 5600 Pac 3500 5500 Accuro Tubes X-act X-dock xam xdock xact CMS Adams Fire 800-942-5880 Draeger Drager Dräger X-am 2500 5000 5600 Pac 3500 5500 Accuro Tubes X-act X-dock xam xdock xact CMS

 

 

 

 

 

 

Automatic bump tests, calibration, reduced test gas consumption,

short testing times and comprehensive documentation come

standard in this new device from Draeger, the experts in gas

detection.

 

 

Adams Fire 800-942-5880 Draeger Drager Dräger X-am 2500 5000 5600 Pac 3500 5500 Accuro Tubes X-act X-dock xam xdock xact CMS

 

The X-dock’s engineered advantage all starts with intuitive touchscreen operation

at the master controller station where up to three test routines can be configured.

Testing is as simple as inserting your Draeger gas detection instrument and

closing the lid. The X-dock immediately detects all sensor combinations and

automatically tests and adjusts when all of the required test gases are connected.

All generated data is documented in the database.

 

Adams Fire 800-942-5880 Draeger Drager Dräger X-am 2500 5000 5600 Pac 3500 5500 Accuro Tubes X-act X-dock xam xdock xact CMS

 

Adams Fire 800-942-5880 Draeger Drager Dräger X-am 2500 5000 5600 Pac 3500 5500 Accuro Tubes X-act X-dock xam xdock xact CMS

 

 

COMPREHENSIVE DOCUMENTATION

All of the relevant data from the test is collected for detailed evaluations

providing you with the tools for unparalleled analytics. The report wizard

can be used to create customized reports and calibration certificates can be

printed right at the stations via PostScript-compatible USB printers. Also

documented are items such as instrument operational status and name

of tester.

CONVENIENCE AND CONTROL

The X-dock Manager software produces a detailed evaluation of the data in

the calibration system and gas detection instruments, and presents the

information in various graphics and statistical models – providing you with a

comprehensive overview of all results. Multiple X-dock systems can be

connected in a network giving all users access to data in a central

database.

CONFIGURATIONS FOR EVERY NEED

The Dräger X-dock comes in multiple configurations to allow for flexibility

depending on the type of detection instrumentation being used.

The X-dock 5300 includes a master controller with a module for a single gas

detection instrument in the X-am 1/2/5000 or Pac

 

 

1) The X-dock 6300 and 6600 versions can be configured with a reduced gas flow

(300 mL/min instead of 500 mL/min = 40 % decrease)

TIME IS MONEY. YOU SAVE BOTH WITH THE X-DOCK

Up to 10 modules can be connected to the X-dock, allowing you to test gas

detection instruments simultaneously or independently of each other. The automatic

bump test also saves time, because the test only takes 8 to 15 seconds. All

Dräger test gas cylinders are already stored in the database – just enter the

part number to automatically fill the fields required for the gas configuration, eliminating

the need for manual data entry

FURTHER BENEFITS

– Touchscreen operation at the master controller station

– Up to three configurable test routines

– Automatic permeability tests

– Automatic tests of all alarm elements

(acoustic, visual and vibration alarms)

– Optional charging function for X-am 1/2/5x00

– Easy to replace seal cartridge

– 12V operation (e.g., in vehicles) vailable

– Can be subsequently expanded with up to max. 10 modules (X-dock 6300/6600)

– Sensor performance testing

Short testing times also reduce the overall maintenance requirements.

Draeger‘s patent pending innovative valve concept only needs one pump, which

means less wear on parts for you. The valves automatically

per module, you save money on test gases.

 

 

 

 

 

switch the test gases and the fresh air source as well.

 

Adams Fire 800-942-5880 Draeger Drager Dräger X-am 2500 5000 5600 Pac 3500 5500 Accuro Tubes X-act X-dock xam xdock xact CMS

THE X-DOCK MANAGER OFFERS

 

– An overview page

– Gas exposure in specific areas,

– Number of executed tests

– Device availability

– Overview of created/sent reports

– Templates for regular reports

– An issue and return function

– Monitoring of stations in the network

– Overview of devices

TECHNICAL DATA

Dräger X-dock 5300/6300/6600

X-dock Master Controller dimensions Approx. 120 x 130 x 250 mm

X-dock Module dimensions Approx. 90 x 145 x 250 mm

Protection class IP20 Yes

Power pack/power supply ViVia 24 V (8321849 & 8321850) power pack or car adapter

Approvals CE marking

Ambient conditions 0 °C to 40 °C

Gas connections

Dräger X-dock 5300 / 6300 3 test gas inlets for connecting 3 different test gases + one fresh air inlet + one exhaust gas outlet

Dräger X-dock 6600 6 test gas inlets for connecting 6 different test gases + one fresh air inlet + one exhaust gas outlet

 

 

 

 

 

 

 

 



Sort by:
8321880 Dräger/Draeger X-dock 5300 X-am 125 Set consisting of on
$0.00
8321880 Dräger/Draeger X-dock 5300 X-am 125 Set consisting of on
8321880 Dräger/Draeger X-dock 5300 X-am 125 Set consisting of one master (3 gases) with power supply and one instrument module for the instruments Drager X-am 125 Limit to 1 module *Order Needed Regulator(s) Separately
[Product Details...]

8321881 Draeger X-dock 5300 PAC Set consisting of one master (3
$0.00
8321881 Draeger X-dock 5300 PAC Set consisting of one master (3
8321881 Draeger X-dock 5300 PAC Set consisting of one master (3 gases) with power supply and one instrument module for the instruments Drager Pac 3500/5500 and Draeger Pac 7000 Limit to 1 module *Order Needed Regulator(s) Separately
[Product Details...]


8321900 Draeger X-dock 6300 Master With 3 test gas connections p
$0.00
8321900 Draeger X-dock 6300 Master With 3 test gas connections p
8321900 Draeger X-dock 6300 Master With 3 test gas connections plus fresh air. At least 1 module must be ordered, extendable to max. 10 modules *Order Needed Regulator(s) and Power Supply Separately
[Product Details...]

8321901 Draeger X-dock 6600 Master With 6 test gas connections p
$0.00
8321901 Draeger X-dock 6600 Master With 6 test gas connections p
8321901 Draeger X-dock 6600 Master With 6 test gas connections plus fresh air. At least 1 module must be ordered, extendable to max. 10 modules *Order Needed Regulator(s) and Power Supply Separately
[Product Details...]


8324260 Draeger X-dock Module X-am 125 Cradle module for one ins
$0.00
8324260 Draeger X-dock Module X-am 125 Cradle module for one ins
8324260 Draeger X-dock Module X-am 125 Cradle module for one instrument of the Draeger X-am 125 series
[Product Details...]

8324261 Draeger X-dock Module X-am 125+ Cradle module for one in
$0.00
8324261 Draeger X-dock Module X-am 125+ Cradle module for one in
8324261 Draeger X-dock Module X-am 125+ Cradle module for one instrument of the Draeger X-am 125 series With an additional charging function
[Product Details...]


8324262 Draeger X-dock Module PAC Cradle module for one instrume
$0.00
8324262 Draeger X-dock Module PAC Cradle module for one instrume
8324262 Draeger X-dock Module PAC Cradle module for one instrument of the Draeger Pac series
[Product Details...]


  • «« Start
  • « Prev
  • 1
  • Next »
  • End »»


Display #  
Results 1 - 7 of 7