GROVES READY RACK FH2G FIREFIGHTER TURNOUT GEAR FIREHOUSE EXPRES |
|||||
Price per Unit (piece):
Call for Pricing
|
||||||
Ask a question about this product | ||||||
GROVES READY RACK FH2G FIREHOUSE EXPRESS DRYER FOR UP TO TWO SETS OF TURNOUT GEAR
The Groves FH2G Firehouse Express Dryer boasts an impressive 900 CFM that can dry turnout gear in an about three hours The Groves FH2G Dryer offers Commercial Grade Construction and can dry turnout gear, hose, dive suits & much more with no additional accessories required The Groves FH2G Dryer system includes four hangers and three shelves The Groves Ready Rack FH2G Firehouse Express Dryer for up to two sets of turnout bunker gear is NFPA 1851 Compliant and comes with an Industry Leading 10-Year Warranty The Groves Ready Rack FH2G Firehouse Express Dryer comes complete with three - 500 W Heating Elements for a total of 1,500 W Total power
Features of the Groves FH2G Dryer Cabinet • Robust and heavy-duty galvanized steel parts • Able to provide either unvented or vented process. • Dry either with up to 1500W of heated air or with ambient air. • Easy to operate NFPA 1851 compliant controls. • 3 adjustable rugged glide out galvanized wire shelves
When selecting a location consider the units’ 600 pound weight and dimensions of 36.0” (W) x 32.5” (L) x 82.0” (H) and also add 30.5” for door clearance The Groves FH2G 2 station dryer should not be positioned in basements, outdoors or unheated areas. If acceptable air flow in the area is not available, the FH2G 2 station dryer should be changed to ducted operation. Placement in unvented or sub-grade internal areas with restricted air circulation can produce mold or mildew circumstances.
The Groves Ready Rack FH2G Firehouse Express Dryer can be positioned within one to two inches of a wall, as long as ten to twelve inches of clearance is obtainable on the sides of the unit to allow the door to open fully. Turnout gear has to be maintained in a clean state so that it can perform correctly and to its specifications. Turnout gear that is soiled and contaminated doesn’t have the correct insulation, can conduct heat, is deficient in its water repellent assets and can potentially be flammable, but more importantly the contaminants embedded in the turnout gear is toxic and carcinogenic. ELECTRICAL SPECIFICATIONS: 120V/1PH/60HZ – Recommended Breaker - 20 A FH2G DRYING CABINET OPERATION
Simple Operation STEP 1 Place turnout gear or hose into the dryer. Close dryer door and close the latch. STEP 2 Press the “MODE/SELECT” for up to 5 seconds to activate the panel. The “ON ENABLE” light will turn GREEN. Push the “MODE/SELECT” once to turn “FAN ON ONLY”. “FAN ON ONLY” light will turn YELLOW. Push the “MODE/SELECT” 1 more time to turn “FAN & HEATER ON”. “FAN & HEATER” light will turn RED. Push the “MODE/SELECT” 1 more time will turn panel OFF. STEP 3 First choose the equipment that will be placed in the dryer. Pre-set times of 10 Hours for hose and 3 hours for gear. STEP 4 Change time as needed by pushing the “HOURS” or “MIN” button. Use the “ARROW DOWN” or “ARROW UP “to amend time. STEP 5 Push the “START/STOP” button to start the drying process At the end of the cycle the FH2G dryer unit will automatically turn off. The FH2G drying cabinet is an important part in complying with the NFPA 1851: Standard on Selection Care and Maintenance of Structural Firefighting Protective Ensembles. Appropriate drying is important for the upkeep, endurance and safety of turnout gear.
With correct preparation and utilization of the Groves FH2G Firehouse Express Dryer you are able to place turnout gear back into service faster and in superior condition than other methods.
In preparation of using the Groves FH2G Firehouse Express Dryer be sure that the turnout gear has been appropriately cleaned of all impurities via the proper choice and usage of detergent and turnout gear cleaning systems. You can place boots, gloves and hoods either directly on the mesh shelving or on hangars.
Safeguard that all articles are straighten out and not twisted. For standard drying operations with the Firehouse Express dryer when the turnout gear has not been soaking or rinsed the jackets, liners and pants can be suspended as a set. Appropriate drying depends on several circumstances most of which are controlled by the user. The dryer controls will guarantee that the equipment will not be extremely heated; the user can select to use heated or ambient air contingent on the environment within the station.
Confirm that the turnout gear is situated properly in the cabinet when loading. Assure that the doors of the dryer are properly secured and the seals are in good condition. The turnout gear should be balanced in the dryer to be properly dried to the conditions such as a fire station that is warm and humid the drying duration will be lengthier to dry than a dry station. Utilizing an appropriate extractor will necessitate less moisture to be removed by the dryer. Proper NFPA 1851 Instructional Training can facilitate your department to fulfill the requirements of the NFPA 1851 Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural and Proximity Fire Fighting. Organizations that require written confirmation of their training in advanced cleaning and advanced inspection should contact their turnout gear manufacturer for training opportunities such as NFPA 1851 Advanced Inspection and NFPA 1851 Moisture Barrier Evaluation. The dryer facilitates turnout gear drying out of direct sunlight where UV exposure can damage its fibers
Always locate the dryer on a level surface. The FH2G dryer has four adjustable feet. These four adjustable feet can be attuned using an adjustable wrench. If the foot retaining nut or top nut loosens they can be made secure utilizing a 15/16” deep socket and a 15/16” wrench. The Groves FH2G Dryer cabinet will turn during levelling, be sure to check the correct alignment of the door in the frame throughout levelling. The door must not swing or bind by itself when the FH2G cabinet is correctly levelled.
RELATED PRODUCTS
MANUFACTURER LINKS FIREHOUSE 2 GEAR EXPRESS DRYER Adams Fire Protection Groves Ready Red Rack 6 FH6G FH2G washer EXTRACTOR EW30 EW22 ppe-ew firefighting firefighter fire department ppe turnout bunker gear decon milnor Huebsch unimac Adams Fire Protection Groves Ready Red Rack FIREHOUSE 6 2 GEAR EXPRESS DRYER FH6G FH2G washer EXTRACTOR EW30 EW22 ppe-ew firefighting firefighter fire department EMS EMT paramedic iaff iafc usfa nfpa 1851 osha niosh cdc compliant decontamination program high higher risk cancer causing agents toxins contaminants hydrocarbons hazardous materials prevention carcinogens soot carbon smoke skin face neck head arms body dermal cleaner best better top rated most effective convenient preferred least expensive first choice eliminate #proventoprotect Benzopyrene BaP support network PPE turnout bunker gear storage unimac V-Line Laundry San CONTINENTAL GIRBAU E-SERIES expressdry adc ram air unilinc optispray UWT Huebsch Speed Queen FIRE WASH soaps spot haz soak Gear Guardian milnor rinsave MWT 30015 30022 mwr 36026 e series g flex rem lg
|
||||||
|
||||||