Your Cart

Products

PrintE-mail
Streamlight Vulcan 180 Vehicle Mount System - 12V DC direct wireDraeger Pac 6000 Portable Personal Single Gas Monitor for CO (Ca



Draeger Single Gas Detection Monitors

Draeger Single Gas Detection Monitors (31)


Draeger Multi Gas Detection Monitors

Draeger Multi Gas Detection Monitors (52)


Draeger CMS (Chip Measurement System)

Draeger CMS (Chip Measurement System) (10)


Draeger PID's (Photo Ionization Detectors)

Draeger PID's (Photo Ionization Detectors) (7)


Draeger Tubes

Draeger Tubes (192)


Draeger Calibration Accessories & Systems

Draeger Calibration Accessories & Systems (7)


Hydrogen Sulfide (H2S) Monitoring

Hydrogen Sulfide (H2S) Monitoring (2)

Draeger X-act 7000 Part Number 8610800

 ( Draeger )
Draeger X-act 7000 Part Number 8610800
View Full-Size Image


Call for Pricing


Draeger X-act 7000

 

 

Draeger Drager Dragger X-act 7000 Xact Micro Tubes Detector Adams Fire 800-942-5880

The ground-breaking Draeger X-act 7000 analysis system comprises Draeger MicroTubes and an optoelectronic analysis unit that lets you precisely measure gases in the low parts per billion (ppb) range. The Draeger X-act 7000 delivers precise results right on site. This replaces slow and costly lab analysis. It's tremendously easy to use, simply insert the Draeger MicroTubes, begin measuring, then examine the test result.

 

Drager Draeger Dragger Dräger x-act 7000 xact 7000 coupler X-am Pump MicroTubes Benzene Butadiene Ethylene oxide Formaldehyde Mercury PPB parts per billion 8610600 8610030 8610460 8610300 8610580 8610200 8610540 8610100 8610350 8610800 8610810 3701985 3702013 8326823 8326824

 

Concentrations of dangerous substances in ambient work area air must never surpass the well-defined limits. Monitoring these sometimes extremely small concentration levels is a responsible job. The Draeger X-act 7000 in conjunction with Draeger MicroTubes is focused on measuring carcinogenic and toxic substances in the low parts per billion (ppb) range. This sensitive analysis arrangement is grounded on colorimetric chemical sensors. These can substitute for conventional laboratory examination and deliver precise results right on site.

 

Drager Draeger Dragger Dräger x-act 7000 xact 7000 coupler X-am Pump MicroTubes Benzene Butadiene Ethylene oxide Formaldehyde Mercury PPB parts per billion 8610600 8610030 8610460 8610300 8610580 8610200 8610540 8610100 8610350 8610800 8610810 3701985 3702013 8326823 8326824 Pac X-am Xam X-zone Xzone x-dock xdock accuro 2500 3500 5000 5100 5300 5500 5600 6000 6300 6500 6600 7000 8000 8500 multi single Gas detector detection monitor meter tubes PID VOC calibration photoionization photo ionization tube pump ADAMSFIRE O2 CO NO2 SO2 H2S CH4 CO2 Cl2 HCN NH3 NO PH3

 

The material specific reactive layers and numerous prelayers in the Draeger MicroTubes permit specific gas analysis. The numerous layers act as a filter. Throughout testing they filter out additional materials that arise in the workplace so that only the target gas is shown in the test result. This significantly removes cross sensitivities and decreases the amount of false/positive test results and alarms.


Drager Draeger Dragger Dräger x-act 7000 xact 7000 coupler X-am Pump MicroTubes Benzene Butadiene Ethylene oxide Formaldehyde Mercury PPB parts per billion 8610600 8610030 8610460 8610300 8610580 8610200 8610540 8610100 8610350 8610800 8610810 3701985 3702013 8326823 8326824


The RFID tags adhered to the Draeger MicroTubes hold all the calibration information that apply during their standard lifetime of 1 year. This removes the requirement for long function assessments and manual calibration. Because it works based on mass flow measurement, air pressure variations do not impact on the unit.



All likely temperature and humidity effects have already been accounted for during the factory calibration. The X-act 7000 analyzer is explosion proof and certified under ATEX IECEx for Zone 0. The analyzer is also dust and splash resilient in accordance with IP54. It similarly meets the requirements for electromagnetic compatibility under EN 50270.

 


Drager Draeger Dragger Dräger x-act 7000 xact 7000 coupler X-am xam Pump MicroTubes 8610800 8610810 8327100 3701985 Benzene Butadiene Ethylene oxide Formaldehyde Mercury PPB ppm X-zone xzone X-dock xdock X-pid xpid Tubes Accuro CMS chip Pac 2500 5000 5100 5300 5500 3D 5K 5600 6000 6300 6600 6500 7000 8000 8500 calibration sensor VOC PID Photo ionization single multigas multi gas meter monitor detector detection device

 


After an automatic self-test, the analyzer is instantly prepared for use. It is appropriate for testing with all existing Draeger MicroTubes. Merely insert the correct MicroTube for your testing requirements. The automatic drive easily pulls the MicroTube in and situates it. You regulate the testing via the three-button control and 2.4” color display. As the test finishes, the green LED will illuminate, and a message will be seen on the screen. The X-act 7000 analyzer can store the test result, time and location in the internal data logger and deliver later using the Draeger CC Vision software. The X-act 7000 analyzer is driven by 5 effortlessly replaceable typical batteries. The battery life continues for more than 10 hours of testing and is displayed on the screen.

 

Drager Draeger Dragger Dräger 8610800 X-am X-act X-zone X-dock X-pid xpid Xam Xact Xzone Xdock Tubes Accuro CMS Pac Microtube 2500 3500 5000 5300 5500 5600 6000 6300 6500 6600 8000 8500 VOC PID Benzene gas detector monitor web1Drager Draeger Dragger Dräger 8610800 X-am X-act X-zone X-dock X-pid xpid Xam Xact Xzone Xdock Tubes Accuro CMS Pac Microtube 2500 3500 5000 5300 5500 5600 6000 6300 6500 6600 8000 8500 VOC PID Benzene gas detector monitor web1Drager Draeger Dragger Dräger 8610800 X-am X-act X-zone X-dock X-pid xpid Xam Xact Xzone Xdock Tubes Accuro CMS Pac Microtube 2500 3500 5000 5300 5500 5600 6000 6300 6500 6600 8000 8500 VOC PID Benzene gas detector monitor web1Drager Draeger Dragger Dräger 8610800 X-am X-act X-zone X-dock X-pid xpid Xam Xact Xzone Xdock Tubes Accuro CMS Pac Microtube 2500 3500 5000 5300 5500 5600 6000 6300 6500 6600 8000 8500 VOC PID Benzene gas detector monitor web1


Using the coupler connector piece (Par # 8610810) the Draeger X-am Pump can be modified to the X-act 7000. This permits the user to test for toxic and carcinogenic substances in the parts per billion (ppb) range, even in areas not easily accessible like ducts, pipe or tanks up to 147.6 feet (45 meters). Because the X-am Pump is also certified explosion-proof for Zone 0, it is ideally matched for these duties.

 

 


Drager Draeger Dragger Dräger 8610800 X-am X-act X-zone X-dock X-pid xpid Xam Xact Xzone Xdock Tubes Accuro CMS Pac Microtube 2500 3500 5000 5300 5500 5600 6000 6300 6500 6600 8000 8500 VOC PID Benzene

 

 

Draeger MicroTubes

Each set of MicroTubes, can perform ten tests in succession. The concentrations of dangerous materials are shown on the analyzers’ display. Specific MicroTubes can even permit the user to complete tests in the parts per billion (ppb) range. The RFID tag adhered to the Draeger MicroTube set comprises all the calibration information that apply throug their normal lifecycle of 1 year. This eliminates the need for extensive function tests and manual calibration.


Drager Draeger Dragger Dräger 8610800 X-am X-act X-zone X-dock X-pid xpid Xam Xact Xzone Xdock Tubes Accuro CMS Pac Microtube 2500 3500 5000 5300 5500 5600 6000 6300 6500 6600 8000 8500 VOC PID Benzene



Technical Data

Measuring range and resolution Varies, depending on the Draeger MicroTubes in use

Typical testing time from 5 seconds to 1,200 seconds, depending on the Dräger

MicroTubes in use and the concentration of the test substance.

Ready to use Immediately

Calibration Not necessary

Operating temperature 0 to +40 °C

Storage temperature -20 to +60 °C (Analyzer)

+4 to +25 °C (Draeger MicroTubes)

Air pressure 700 to 1,300 hPa

Humidity 0 to 95 % relative humidity, non-condensing

Recording of measured data CMOS sensor optics and LED light

System diagnostics Automatic, using micro-controllers for all system components

Display 2.4” high contrast, color display with a resolution of 240 x 320, viewing angle of 160°

Menu languages English, German (language selection currently being expanded)

Operating time Approx. 600 minutes of testing time

Power supply 5 x 1.5 volt batteries

Dimensions (L x W x H) 195 mm x 85 mm x 70 mm

Approvals (pending) ATEX/IECEx II 1G Ex ia IIC T4 Ga

Protection class IP54, dust- and splash-resistant



Draeger MicroTubes

Description Test range Test time (min–max) Part number

Benzene 1 – 150 ppb 100 – 900 seconds 8610600

Benzene 0.15 – 10 ppm 25 – 150 seconds 8610030

1.3-Butadiene 25 – 500 ppb 150 – 550 seconds 8610460

1.3-Butadiene 0.5 – 25 ppm 30 – 100 seconds 8610300

Ethylene oxide 25 – 250 ppb 200 – 500 seconds 8610580

Ethylene oxide 0.25 – 10 ppm 50 – 200 seconds 8610200

Formaldehyde 5 – 150 ppb 360 – 960 seconds 8610540

Formaldehyde 0.15 – 3 ppm 300 – 600 seconds 8610100

Mercury 0.005 – 0.25 mg/m3 240 – 1,200 seconds 8610350




Draeger X-act 7000 8610800

Includes basic device X-act 7000 including batteries, shoulder strap, MicroTube Demo, Torx T10 screwdriver, USB cable 2m with Mini connection



Pump accessories

Draeger X-act 7000 Coupler 8610810

Draeger X-am Pump 8327100



Other accessories

Draeger X-act 7000 pre-tube holder 3701985

Draeger Tubes, ppb-Booster Basic 3702013

Tube opener, TO 7000 6401200

Shoulder strap, complete 8326823

Label holder for shoulder strap 8326824

 

 

 

 

The innovative Dräger X-act® 7000 analysis system consists of Dräger MicroTubes and an opto-electronic analysis device that lets you precisely measure gases in the low ppb range. It gives you precise results right on site, replacing slow, expensive lab analyses. It's extremely easy to use: insert the Dräger MicroTubes, start measuring, then read out the test result.